EPRI
Tech Portal
Tech Portal
Tech Portal
  • Home
  • Tech Channels
  • Innovation Areas
  • Cross-Cutting Technology
  • Suggest a Developer
  • About
  • Log In/Register
  • Home
  • Tech Channels
  • Innovation Areas
  • Cross-Cutting Technology
  • Suggest a Developer
  • About
  • Log In/Register
  • EPRI.com
  • Copyright Policy
  • Privacy Statement
  • Terms of Use
  • Help / Contact Us
  • EPRI 3420 Hillview Avenue, Palo Alto,
    California 94304

    © Electric Power Research Institute, Inc.
    2001-2023

    All Rights Reserved

Metamorphosis of Power Distribution: System Services from Photovoltaics (MetaPV)
  1. Home
  2. Tech Channels
  3. Integrated Grid
  4. Metamorphosis of Power Distribution: System Services from Photovoltaics (MetaPV)

Metamorphosis of Power Distribution: System Services from Photovoltaics (MetaPV)

  • Overview
  • Project Information
  • IG sponsors Information

Overview

Project Summary

Adapted and lightly edited from: https://ieeexplore.ieee.org/document/5679214

MetaPV was the first project world-wide that demonstrated the provision of electrical benefits from photovoltaics (PV) on a large scale. Additional benefits for active grid support from PV were demonstrated at two sites: a residential / urban area of 128 households with 4 kWp each, and an industrial zone of 31 PV systems with 200 kWp each. The enhanced control capacities to be implemented into PV inverters and demonstrated were active voltage control, fault ride-through capability, autonomous grid operation, and interaction of distribution system control with PV systems. A detailed technical and economic assessment of the additional services from PV was carried out. The role of PV in an area fully supplied by renewable sources was assessed.

Project Team

  • Project Lead
    1. 3E
  • Utilities
    1. Infrax
  • Research Partners
    1. Austrian Institute of Technology (AIT)
    2. University of Ljubljana
  • Vendors
    1. SMA Solar Technology
  • Other Participants or Stakeholders
  • N/A
Loading...

Project Information

Project Information

  • Technology Demonstrated
    1. Residential Solar PV
    2. Commercial Solar PV
    3. Utility-scale Solar PV
    4. Community Solar PV
    5. Distributed Resource Management System
    6. Smart Inverter
  • Demonstration Objectives
    1. Reliability Improvement
    2. Voltage Regulation
    3. Ancillary Services - Non-Spinning Reserve
    4. Frequency Response
    5. Volt-VAR Optimization
    6. Smart City Infrastructure
    7. Distribution Planning
    8. Delivery Asset Deferral
    9. Improving Power System Models
  • Related EPRI Programs
    1. P174 - Integration of Distributed Energy Resources
    2. P200 - Distribution Operations and Planning
  • Project Type
    1. Laboratory Testing
    2. Modeling and Simulation
    3. Field Deployment
    4. Cost-Benefit Assessment

Status

Beginning Date:
January 8, 2009
Ending Date:
March 9, 2014
Project Status:
Completed
Last Modified:
October 26, 2020

Additional Information

For Additional Information:
  1. http://www.metapv.eu/

IG sponsors Information: Learnings and Recommendations

IG sponsors must Log In to view additional information

EPRI.com|Copyright Policy|Privacy Statement|Terms of Use|Help/Contact Us
EPRI
3420 Hillview Avenue, Palo Alto, California 94304 | 800-313-3774
© Electric Power Research Institute, Inc. 2001-2023. All Rights Reserved